Re: Invalid field variable in property Llimitfivar

$
0
0
Hi,

the problem apear when you change something in the physics node, but not in the study sequence node. For example, if you have a trubulent flow with kappa-omega turbulent model and deciede to take a new one, let's say kappa-epsilon turbulent model. In this case you have just to change the model with one click in the turbulence model type, but the lower limit in the study node will still try to solve for omega and not for epsilon. So in the case you have changed something in the physics, take new study or adapt the old one to the new problem. I hope my example will help you to find the mistake.

Best regards,
Antoni